Benefits of Hard Wired Alarms
& Interconnection

 

 Electrician verifying wiring connections

 

Why Use Hard Wired?

  • The only alarm type that complies with requirements of local Building Regulations is that
    supplied by a mains power source.
    Battery Only alarms are not acceptable.

  • Always interconnectable up to 24 units.
  • Green/Red LED's, indicating healthy power and state of alarm. 

+Kidde offers 10 Year Whole product guarantees for your assurance10 Year Models with sealed in lithium back up

+Far less likely to be tampered with than DC(Battery)  alarms, where battery misappropriation
 is an issue In rented dwellings.
 (e.g. Where the battery is borrowed for use in another household appliance and never
 replaced.)

 Benefits of Interconnection?

  • You enjoy Wide Area Protection:
    This means an alarm downstairs that senses fire at night, will sound all interconnected alarms.
    This extra few minutes of warning to waken the family, can mean the difference between life and death.

    (Hard Wired CO Alarms shown)

Smart interconnect is unique to Kidde Kidde hard wired 423D/9hir CO alarm that signals source of trigger by LED & differing sounds

  • With Kidde's Smart Interconnection feature you can interconnect, AC Smoke, Heat & CO Alarms:
    in a Fire situation all interconnected alarms will sound.
    If a CO alarm is triggered, it will only trigger other Kidde CO alarms.

Kidde's fast fit Slick® range of smoke & heat alarms are fully compatible with the standard
ranges. Q&A sheet here.

  • *Note: if single alarm installation, leave terminal unconnected
    (with sheathing intact on models with cable harness connection; see picture below.)

On cable harness models the interconnect cable is sheathed should it not be required 

  • These are double insulated products and do not need earthing: never use earth conductor to interconnect.
    use 3 core and earth cable.
    Use yellow
    strand or black [ in new 3 core & earth] cabling, for in ter connect line.
  • Interconnect using YELLOW strand on old 3 core & earth cable, or BLACK on New
    harmonised colours;  if interconnecting using old & new cable take
    great care
    / follow IEE Reqs and label at all affected junctions.

  • Hard wired alarms must all be interconnected on one circuit and ideally with a dedicated circuit breaker;
    the previous alternate method of linking in to an adjacent lighting circuit is no longer permitted.
    Lighting circuits have been found to be transmitters of electrical interefernce from sources such as
    Low Voltage lighting transformers, dimmer switches &
    related cabling, electronic ballasts.
    Additionally, the latest UK Wiring Regs refer to "Safety Services" being on a dedicated circuit,
    and the circuit needs the ability to be isolated for maintenance purposes; having lighting on same circuit makes this impractical.
    Our Installer Manuals reflect this new thinking.
    Though our products are tested under the EMC Directive as part of their Kitemark Appproval, other electrical accessories with no such approvals
    Are found in many homes.

Interconnection gives wide area protection around the home


Note since 2005 the colours have changed, as below;
old is on left, new harmonised colour on right.:

Old UK cable colours on left, new on right

Sealed in Battery Back Up 

In our Slick® hard wired ranges of Smoke & Heat Alarms there are
models with sealed in Rechargeable lithium cells back up.
Kidde guarantee the complete product for 10 Years.

The Firex range are guaranteed for 6 years.